Streptavidin (SA) antibody and antigen (hapten, BSA/OVA conjugated)
Diagnostic anti-Streptavidin (SA) antibodies (anti-Streptavidin, anti-SA) and diagnostic hapten-carrier conjugates BSA-Streptavidin (SA), OVA-Streptavidin (SA), KLH-Streptavidin (SA) antigens for Biology SA detection in ELISA test, competitive ELISA, Lateral flow immunoassay (LFIA), CLIA, TINIA and POCT.
Go to Metabolic diseases diagnostics products collection>>
Product information
Size: 1mg | 10mg | 100mg
Catalog No. | Description | US $ Price (per mg) | First Order Discount | First Order Discount Price |
---|---|---|---|---|
GMP-SMT-1766-Ag01 | BSA-Streptavidin (SA) | $756.00 | ||
GMP-SMT-1766-Ag02 | OVA-Streptavidin (SA) | $756.00 | ||
GMP-SMT-1766-HRP | HRP-Streptavidin (SA) | |||
GMP-SMT-1766-nanoIMB | Nano-Immunomagnetic Bead-Streptavidin | |||
GMP-SMT-1766-Ab01 | Anti-human Streptavidin (SA) mouse monoclonal antibody (mAb) | $1953.00 | 20% | $1562.4 |
GMP-SMT-1766-Ab02 | Anti-human Streptavidin (SA) human monoclonal antibody (mAb) | $1953.00 | 20% | $1562.4 |
Shipping Costs: $360–$760
Antibodies: $360 Antigens: $760 (Elevated cost due to antigen heterogeneity, post-translational modifications, structural complexity, and specialized handling.)
Product Description
BSA-Streptavidin (SA)
Cat No. | GMP-SMT-1766-Ag01 |
Product Name | BSA-Streptavidin (SA) |
Target | Streptavidin (SA) |
Expression platform | Synthetic |
Bioactivity validation | Streptavidin (SA) antibodies binding, Immunogen in Sandwich Elisa, lateral-flow tests, and other immunoassays as control material in BT level test of Metabolic diseases (Biotin deficiency) and related syndrome evaluation |
Products description | Competitive immunoassay-validated hapten-carrier conjugates BSA-Streptavidin (SA) / OVA-Streptavidin (SA) is Synthetic. |
Purity | High (TBD) |
Application | Competitive immunoassay validation (Competitive ELISA), ELISA, Lateral flow immunoassay (LFIA),colloidal gold immunochromatographic assay, Chemiluminescent immunoassay (CLIA),turbidimetric inhibition immuno assay (TINIA) and Immunonephelometry. |
Formulation & Reconstitution | Lyophilized from GM's Protein
Stability Buffer2 (PSB2,Confidential Ingredients) or PBS (pH7.4); For PSB2, reconstituted with 0.9% sodium chloride; For PBS, reconstituted with ddH2O. |
Storage | Store at -20℃ to -80℃ under sterile conditions. Avoid repeated freeze-thaw cycles. |
OVA-Streptavidin (SA)
Cat No. | GMP-SMT-1766-Ag02 |
Product Name | OVA-Streptavidin (SA) |
Target | Streptavidin (SA) |
Expression platform | Synthetic |
Bioactivity validation | Streptavidin (SA) antibodies binding, Immunogen in Sandwich Elisa, lateral-flow tests, and other immunoassays as control material in BT level test of Metabolic diseases (Biotin deficiency) and related syndrome evaluation |
Products description | Competitive immunoassay-validated hapten-carrier conjugates BSA-Streptavidin (SA) / OVA-Streptavidin (SA) is Synthetic. |
Purity | High (TBD) |
Application | Competitive immunoassay validation (Competitive ELISA), ELISA, Lateral flow immunoassay (LFIA),colloidal gold immunochromatographic assay, Chemiluminescent immunoassay (CLIA),turbidimetric inhibition immuno assay (TINIA) and Immunonephelometry. |
Formulation & Reconstitution | Lyophilized from GM's Protein
Stability Buffer2 (PSB2,Confidential Ingredients) or PBS (pH7.4); For PSB2, reconstituted with 0.9% sodium chloride; For PBS, reconstituted with ddH2O. |
Storage | Store at -20℃ to -80℃ under sterile conditions. Avoid repeated freeze-thaw cycles. |
HRP-Streptavidin (SA)
Cat No. | GMP-SMT-1766-HRP |
Product Name | HRP-Streptavidin (SA) |
Target | Streptavidin (SA) |
Bioactivity validation | Streptavidin (SA) binding, Competitive immunoassay validation (Competitive ELISA) in biotin level test. |
Products description | Streptavidin (SA)-HRP is a conjugate of SA and horseradish peroxidase. |
Purity | ≥95% |
Application | Western Blotting, and ELISA. |
Formulation & Reconstitution | PBS, pH7.4 with protectant. |
Storage | Store at -20°C under sterile conditions, protected from light. |
Nano-lmmunomagnetic Bead-Streptavidin (SA)
Cat No. | GMP-SMT-1766-nanoIMB |
Product Name | Nano-lmmunomagnetic Bead-Streptavidin (SA) |
Target | Streptavidin (SA) |
Bioactivity validation | Streptavidin (SA) binding, Competitive immunoassay validation (Competitive ELISA) in biotin level test. |
Products description | Streptavidin (SA)-HRP is a conjugate of SA and horseradish peroxidase. |
Purity | ≥95% |
Application | Western Blotting, and ELISA. |
Formulation & Reconstitution | PBS, pH7.4 with protectant. |
Storage | Store at -20°C under sterile conditions, protected from light. |
Anti-human Streptavidin (SA) mouse monoclonal antibody (mAb)
Cat No. | GMP-SMT-1766-Ab01 |
Product Name | Anti-human Streptavidin (SA) mouse monoclonal antibody (mAb) |
Target | Streptavidin (SA) |
Expression platform | hybridoma |
Isotypes | Mouse IgG |
Bioactivity validation | Streptavidin (SA) antigen binding, ELISA validated as capture antibody and detection antibody. Pair recommendation with other Streptavidin (SA) antibodies in BT level test of Metabolic diseases (Biotin deficiency) and related syndrome evaluation. |
Tag | mFc |
Products description | Anti-human Streptavidin (SA) mouse monoclonal antibody (mAb) is a mouse monoclonal antibody produced by hybridoma technology. |
Purity | High (TBD) |
Application | Competitive immunoassay validation (Competitive ELISA), ELISA, Lateral flow immunoassay (LFIA), colloidal gold immunochromatographic assay, Chemiluminescent immunoassay (CLIA), turbidimetric inhibition immuno assay (TINIA) and Immunonephelometry. |
Formulation & Reconstitution | Lyophilized from GM's Protein
Stability Buffer2 (PSB2,Confidential Ingredients) or PBS (pH7.4); For PSB2, reconstituted with 0.9% sodium chloride; For PBS, reconstituted with ddH2O. |
Storage | Store at -20℃ to -80℃ under sterile conditions. Avoid repeated freeze-thaw cycles. |
Anti-human Streptavidin (SA) human monoclonal antibody (mAb)
Cat No. | GMP-SMT-1766-Ab02 |
Product Name | Anti-human Streptavidin (SA) human monoclonal antibody (mAb) |
Target | Streptavidin (SA) |
Expression platform | hybridoma |
Isotypes | Human IgG1 |
Bioactivity validation | Streptavidin (SA) antigen binding, ELISA validated as capture antibody and detection antibody. Pair recommendation with other Streptavidin (SA) antibodies in BT level test of Metabolic diseases (Biotin deficiency) and related syndrome evaluation. |
Tag | hFc |
Products description | Anti-human Streptavidin (SA) mouse monoclonal antibody (mAb) is a human monoclonal antibody produced by CHO. |
Purity | Purity: ≥95% (SDS-PAGE) |
Application | Competitive immunoassay validation (Competitive ELISA), ELISA, Lateral flow immunoassay (LFIA), colloidal gold immunochromatographic assay, Chemiluminescent immunoassay (CLIA), turbidimetric inhibition immuno assay (TINIA) and Immunonephelometry. |
Formulation & Reconstitution | Lyophilized from GM's Protein
Stability Buffer2 (PSB2,Confidential Ingredients) or PBS (pH7.4); For PSB2, reconstituted with 0.9% sodium chloride; For PBS, reconstituted with ddH2O. |
Storage | Store at -20℃ to -80℃ under sterile conditions. Avoid repeated freeze-thaw cycles. |
Reference
Validation Data
Click to get more Data / Case study about the product.
Target/Biomarker information
Biotin in In Vitro Diagnosis (IVD): Biotin, also scientifically referred to as Vitamin B7 or
Vitamin H, emerges as a paramount constituent within the intricate framework of in vitro
diagnosis (IVD). Its role within this domain is multifaceted, manifesting as a cornerstone in
numerous assay systems and diagnostic methodologies. Biotin's intrinsic significance primarily
emanates from its capacity to serve as a conjugate or label in immunoassays and other
sophisticated detection mechanisms harnessed extensively in IVD.
In the specific context
of IVD, Biotin finds profound utility as a conjugate. It becomes covalently linked to carrier
proteins, such as Bovine Serum Albumin (BSA) or Ovalbumin (OVA), resulting in the formation of
Biotinylated antigens. These Biotinylated antigens then embark on a pivotal journey as they are
deployed to ascertain the presence or quantify the concentration of particular antibodies or
analytes within patient specimens. A remarkable facet of Biotin lies in its exceptional binding
affinity, particularly with Avidin or Streptavidin proteins, which renders it indispensable in
assays of paramount importance. Assay methodologies such as enzyme-linked immunosorbent assays
(ELISAs) and chemiluminescent immunoassays (CLIAs) stand as exemplars, where Biotinylated
reagents underpin precision, sensitivity, and ultimately, the accuracy of diagnostic detection.
Significance of Biotin Measurement in IVD:
a. Quality Assurance (QA) and Control
(QC): The meticulous measurement of Biotin holds a pivotal role in ensuring the veracity of in
vitro diagnostic assays. This veracity hinges upon the quality and consistency of Biotinylated
reagents, encompassing Biotin-conjugated antigens and antibodies. Rigorous measurement,
therefore, assumes an indispensable role in quality assurance (QA) and control (QC) protocols,
bolstering the generation of dependable assay outcomes. As Biotin is an elemental component of
these reagents, precise measurement becomes pivotal to ascertain the optimal concentration and
functionality of these diagnostic entities.
b. Augmented Assay Sensitivity and
Specificity: Within the intricate tapestry of in vitro diagnostic assays, the precise
measurement of Biotin levels stands as a linchpin in optimizing assay parameters. Fine-tuning
the concentration of Biotinylated reagents within assays is an imperative step in achieving
heightened sensitivity and specificity. By deciphering the precise Biotin levels required,
diagnostic tests become adept at discriminating minute variations in analyte concentrations,
thereby augmenting their clinical utility and diagnostic accuracy.
c. Mitigating Biotin
Interference: Biotin interference represents a substantial concern in specific clinical assays.
Elevated Biotin levels within patient specimens can potentially induce spurious results, leading
to erroneous clinical interpretations. Precise measurement of Biotin levels within patient
samples facilitates the identification of potential interference instances, empowering
laboratory professionals to implement necessary protocol adjustments and ensure the reliability
of assay results.
d. Patient Biotin Level Monitoring: In selected clinical scenarios,
the monitoring of Biotin levels within patients' biological matrices assumes clinical relevance.
Excessive Biotin supplementation, either through dietary sources or supplements, can exert
significant interference with laboratory test results. This interference is particularly
pertinent in hormone assays. Comprehensive knowledge of a patient's Biotin levels enables
healthcare practitioners to judiciously interpret test outcomes, ensuring that diagnostic
conclusions are founded on accurate and unbiased data.
In summation, the meticulous
measurement of Biotin is an elemental and non-negotiable facet of in vitro diagnosis (IVD),
pivotal for safeguarding the precision, sensitivity, and reliability of diagnostic assays
reliant on Biotinylated reagents. It constitutes an indispensable element within the ambit of
IVD, underpinning the scientific and clinical rigor of modern diagnostic practices. The careful
consideration and precise measurement of Biotin levels serve as the bedrock upon which accurate
clinical diagnoses are made, thereby shaping the landscape of healthcare and patient management.
About GDU
GDU helps global diagnostic partners in high quality of raw material discovery, development, and application. GDU believes in Protein&antibody Innovation for more reliable diagnostic solutions.