Estrone (E1) antibody and antigen (hapten, BSA/OVA conjugated)
Diagnostic anti-Estrone (E1) antibodies (anti-Estrone, anti-E1) and diagnostic hapten-carrier conjugates BSA-Estrone (E1), OVA-Estrone (E1), KLH-Estrone (E1) antigens for Hormone disorders E1 detection in ELISA test, competitive ELISA, Lateral flow immunoassay (LFIA), CLIA, TINIA and POCT.
Go to Neurodegenerative diseases diagnostics products collection >>
Product information
Catalog No. | Description | US $ Price (per mg) |
---|---|---|
GMP-SMT-E1-Ag01 | BSA-Estrone (E1) | 756 |
GMP-SMT-E1-Ag02 | OVA-Estrone (E1) | 756 |
GMP-SMT-E1-Ab01 | Anti-human Estrone (E1) mouse monoclonal antibody (mAb) | 1953 |
GMP-SMT-E1-Ab02 | Anti-human Estrone (E1) human monoclonal antibody (mAb) | 1953 |
Size: 1mg | 10mg | 100mg
Product Description
Cat No. of Products | GMP-SMT-E1-Ag01 |
Product Name | BSA-Estrone (E1) |
Target/Biomarker | Estrone (E1) |
Expression platform | Synthetic |
Isotypes | NA |
Bioactivity validation | Estrone (E1) antibodies binding, Immunogen in Sandwich Elisa, lateral-flow tests, and other immunoassays as control material in E1 level test of Hormone disorders (irregular bleeding, fatigue or mood swings) and related syndrome evaluation. |
Tag | NA |
Products description | Competitive immunoassay-validated hapten-carrier conjugates BSA-Estrone (E1) / OVA-Estrone (E1) is Synthetic. |
Purity | Purity: ≥95% (SDS-PAGE) |
Application | Competitive immunoassay validation (Competitive ELISA), ELISA, Lateral flow immunoassay (LFIA),colloidal gold immunochromatographic assay, Chemiluminescent immunoassay (CLIA),turbidimetric inhibition immuno assay (TINIA) and Immunonephelometry. |
Formulation | Supplied as a 0.2 μM filtered solution of PBS,PH7.4. |
Storage | Store at -20℃ to -80℃ under sterile conditions. Avoid repeated freeze-thaw cycles. |
Cat No. of Products | GMP-SMT-E1-Ag02 |
Product Name | OVA-Estrone (E1) |
Target/Biomarker | Estrone (E1) |
Expression platform | Synthetic |
Isotypes | NA |
Bioactivity validation | Estrone (E1) antibodies binding, Immunogen in Sandwich Elisa, lateral-flow tests, and other immunoassays as control material in E1 level test of Hormone disorders (irregular bleeding, fatigue or mood swings) and related syndrome evaluation. |
Tag | NA |
Products description | Competitive immunoassay-validated hapten-carrier conjugates BSA-Estrone (E1) / OVA-Estrone (E1) is Synthetic. |
Purity | Purity: ≥95% (SDS-PAGE) |
Application | Competitive immunoassay validation (Competitive ELISA), ELISA, Lateral flow immunoassay (LFIA),colloidal gold immunochromatographic assay, Chemiluminescent immunoassay (CLIA),turbidimetric inhibition immuno assay (TINIA) and Immunonephelometry. |
Formulation | Supplied as a 0.2 μM filtered solution of PBS,PH7.4. |
Storage | Store at -20℃ to -80℃ under sterile conditions. Avoid repeated freeze-thaw cycles. |
Cat No. of Products | GMP-SMT-E1-Ab01 |
Product Name | Anti-human Estrone (E1) mouse monoclonal antibody (mAb) |
Target/Biomarker | Estrone (E1) |
Expression platform | Hybridoma |
Isotypes | Mouse IgG |
Bioactivity validation | Estrone (E1) antibodies binding, Immunogen in Sandwich Elisa, lateral-flow tests, and other immunoassays as control material in E1 level test of Hormone disorders (irregular bleeding, fatigue or mood swings) and related syndrome evaluation. |
Tag | mFc |
Products description | Competitive immunoassay-validated hapten-carrier conjugates BSA-Estrone (E1) / OVA-Estrone (E1) is Synthetic. |
Purity | Purity: ≥95% (SDS-PAGE) |
Application | Competitive immunoassay validation (Competitive ELISA),Lateral flow immunoassay (LFIA),colloidal gold immunochromatographic assay, Chemiluminescent immunoassay (CLIA),turbidimetric inhibition immuno assay (TINIA) and Immunonephelometry. |
Formulation | Supplied as a 0.2 μM filtered solution of PBS,PH7.4. |
Storage | Store at -20℃ to -80℃ under sterile conditions. Avoid repeated freeze-thaw cycles. |
Cat No. of Products | GMP-SMT-E1-Ab02 |
Product Name | Anti-human Estrone (E1) human monoclonal antibody (mAb) |
Target/Biomarker | Estrone (E1) |
Expression platform | Hybridoma |
Isotypes | Mouse IgG |
Bioactivity validation | Estrone (E1) antibodies binding, Immunogen in Sandwich Elisa, lateral-flow tests, and other immunoassays as control material in E1 level test of Hormone disorders (irregular bleeding, fatigue or mood swings) and related syndrome evaluation. |
Tag | mFc |
Products description | Competitive immunoassay-validated hapten-carrier conjugates BSA-Estrone (E1) / OVA-Estrone (E1) is Synthetic. |
Purity | Purity: ≥95% (SDS-PAGE) |
Application | Competitive immunoassay validation (Competitive ELISA),Lateral flow immunoassay (LFIA),colloidal gold immunochromatographic assay, Chemiluminescent immunoassay (CLIA),turbidimetric inhibition immuno assay (TINIA) and Immunonephelometry. |
Formulation | Supplied as a 0.2 μM filtered solution of PBS,PH7.4. |
Storage | Store at -20℃ to -80℃ under sterile conditions. Avoid repeated freeze-thaw cycles. |
Reference
Validation Data
Click to get more Data / Case study about the product.
Target/Biomarker information
Estrone is a female sex hormone. The weakest type of estrogen, it’s typically higher after menopause. Like all estrogen, estrone supports female sexual development and function. Low or high estrone can cause symptoms such as irregular bleeding, fatigue or mood swings.