Chlortetracycline antibody/antigen (BSA/OVA/KLH conjugated hapten)

anti-Chlortetracycline antibody and Carrier-coupled antigen/immunogen (hapten-carrier conjugates)

Target products collectionGo to Antibiotics diagnostics products collection >>


Product information

Catalog No. Description US $ Price (per mg)
GMP-SMT-50-1 1. BSA-Chlortetracycline
2. Anti-Chlortetracycline mouse monoclonal antibody
$2709.00
GMP-SMT-50-2 1. OVA-Chlortetracycline
2. Anti-Chlortetracycline mouse monoclonal antibody
$2709.00
GMP-SMT-50-3 1. BSA-Chlortetracycline
2. Anti-Chlortetracycline human monoclonal antibody
$2709.00
GMP-SMT-50-4 1. OVA-Chlortetracycline
2. Anti-Chlortetracycline human monoclonal antibody
$2709.00
GMP-SMT-50-Ag-1 BSA-Chlortetracycline $756.00
GMP-SMT-50-Ag-2 OVA-Chlortetracycline $756.00
GMP-SMT-50-Ab-1 Anti-Chlortetracycline mouse monoclonal antibody $1953.00
GMP-SMT-50-Ab-2 Anti-Chlortetracycline human monoclonal antibody $1953.00

Size: 1mg | 10mg | 100mg



Product Description


BSA-Chlortetracycline

Cat No. GMP-SMT-50-Ag-1
Bioactivity validation Competitive immunoassay validation (Competitive ELISA) with hapten-carrier conjugates and anti-Hapten antibody;
Products description Competitive immunoassay-validated hapten-carrier conjugates BSA-Chlortetracycline with anti-Hapten antibody. The hapten hapten-carrier conjugates BSA-Chlortetracycline had been validated with our anti-Hapten antibody Anti-Chlortetracycline mouse monoclonal antibody via competitive ELISA test.
Application ELISA tests and other immunoassays;
Lateral flow immunoassay (LFIA);
LTIA
Immunonephelometry
Time-resolved Fluorescence Immunoassay (TRFIA)
Formulation Lyophilized from sterile PBS, PH 7.4
Storage Store at -20℃ to -80℃ under sterile conditions. Avoid repeated freeze-thaw cycles.


OVA-Chlortetracycline

Cat No. GMP-SMT-50-Ag-2
Bioactivity validation Competitive immunoassay validation (Competitive ELISA) with hapten-carrier conjugates and anti-Hapten antibody;
Products description Competitive immunoassay-validated hapten-carrier conjugates OVA-Chlortetracycline with anti-Hapten antibody. The hapten hapten-carrier conjugates OVA-Chlortetracycline had been validated with our anti-Hapten antibody Anti-Chlortetracycline mouse monoclonal antibody via competitive ELISA test.
Application ELISA tests and other immunoassays;
Lateral flow immunoassay (LFIA);
LTIA
Immunonephelometry
Time-resolved Fluorescence Immunoassay (TRFIA)
Formulation Lyophilized from sterile PBS, PH 7.4
Storage Store at -20℃ to -80℃ under sterile conditions. Avoid repeated freeze-thaw cycles.


Anti-Chlortetracycline mouse monoclonal antibody

Cat No. GMP-SMT-50-Ab-1
Host of Antibody Mouse IgG
Bioactivity validation Competitive immunoassay validation (Competitive ELISA) with hapten-carrier conjugates and anti-Hapten antibody;
Lateral flow immunoassay (LFIA);
ELISA IC50 (ppb) 0.3-0.5
Products description The anti-Hapten antibody against hapten Chlortetracycline had been validated with our hapten hapten-carrier conjugates BSA-Chlortetracycline via competitive ELISA test.
Application ELISA tests and other immunoassays;
Lateral flow immunoassay (LFIA);
LTIA
Immunonephelometry
Time-resolved Fluorescence Immunoassay (TRFIA)
Formulation Lyophilized from sterile PBS, PH 7.4
Storage Store at -20℃ to -80℃ under sterile conditions. Avoid repeated freeze-thaw cycles.


Anti-Chlortetracycline human monoclonal antibody

Cat No. GMP-SMT-50-Ab-2
Host of Antibody Human IgG1
Bioactivity validation Competitive immunoassay validation (Competitive ELISA) with hapten-carrier conjugates and anti-Hapten antibody;
Lateral flow immunoassay (LFIA);
ELISA IC50 (ppb) 0.3-0.5
Products description The anti-Hapten antibody against hapten Chlortetracycline had been validated with our hapten hapten-carrier conjugates BSA-Chlortetracycline via competitive ELISA test.
Application ELISA tests and other immunoassays;
Lateral flow immunoassay (LFIA);
LTIA
Immunonephelometry
Time-resolved Fluorescence Immunoassay (TRFIA)
Formulation Lyophilized from sterile PBS, PH 7.4
Storage Store at -20℃ to -80℃ under sterile conditions. Avoid repeated freeze-thaw cycles.


Reference




    Validation Data


    Picture loading failed.

    Figure: GeneMedi's GMP-SMT-48-Ab-1 is validated to detect the GMP-SMT-48-Ag-1 in ELISA. IC50=0.390 ppb.


    Click to get more Data / Case study about the product.



    Biomarker Information


    1. Chlortetracycline in Veterinary Drug Residues and Additives

    Serial Number: 1

    Chlortetracycline, a member of the tetracycline antibiotic family, is a vital component in the field of veterinary medicine. Its broad-spectrum antimicrobial properties make it indispensable for managing and preventing bacterial infections in animals. In this comprehensive exploration, we delve into the multifaceted role of chlortetracycline in veterinary drug residues and additives.

    2. The Significance of Chlortetracycline

    Serial Number: 2

    Chlortetracycline's significance in veterinary medicine cannot be overstated. It serves as an essential tool in safeguarding the health and welfare of livestock and poultry populations. By effectively combating a wide range of Gram-positive and Gram-negative bacteria, chlortetracycline plays a pivotal role in maintaining the overall well-being of animals within the food production chain.

    3. The Necessity of Monitoring Chlortetracycline Levels

    Serial Number: 3

    Accurate and regular monitoring of chlortetracycline levels is paramount for several critical reasons, particularly in the realm of veterinary and food safety.

    1.Regulatory Compliance: Chlortetracycline levels in animal products are subject to stringent regulatory thresholds. Ensuring that these levels are consistently within acceptable limits is vital to adhere to regulatory standards and prevent any potential breaches in food safety protocols.

    2.Antibiotic Resistance Control: Excessive usage of chlortetracycline can contribute to the development of antibiotic-resistant strains of bacteria, presenting a significant global health challenge. Careful monitoring helps in controlling the proliferation of such resistant strains, thereby preserving the efficacy of this antibiotic for both veterinary and human use.

    3.Animal Health Preservation: Precise measurement of chlortetracycline levels aids in maintaining the overall health and welfare of animals. By minimizing the spread of bacterial diseases among livestock and poultry populations, it helps ensure the sustainable and humane treatment of these animals.

    4.Consumer Protection: In an era where consumers demand safe and wholesome food products, regular monitoring of chlortetracycline levels is vital. It ensures that animal-derived products are free from harmful residues, thereby safeguarding consumer well-being and confidence in the food supply chain.

    4. Chlortetracycline Measurement Methods

    Serial Number: 4

    To effectively monitor chlortetracycline levels, various measurement methods and techniques are employed. These methods often include advanced analytical techniques such as liquid chromatography-mass spectrometry (LC-MS) and high-performance liquid chromatography (HPLC). These techniques allow for the precise quantification of chlortetracycline residues in animal-derived products and feed.

    Moreover, immunoassays, such as enzyme-linked immunosorbent assays (ELISA), are increasingly utilized in chlortetracycline measurement due to their sensitivity and specificity. ELISA tests employ antibodies that are highly selective to chlortetracycline, allowing for accurate detection and quantification.

    5. The Role of Antibodies and Antigens

    Serial Number: 5

    In the field of chlortetracycline measurement, antibodies and antigens play a pivotal role. Anti-chlortetracycline antibodies are specifically designed to recognize and bind to chlortetracycline molecules. This binding event is then quantified using various methods, allowing for the accurate determination of chlortetracycline concentrations in samples.

    Competitive antigens, on the other hand, are utilized in immunoassays to compete with chlortetracycline in binding to the anti-chlortetracycline antibodies. The extent of competition between the antigen and chlortetracycline provides valuable information about the concentration of chlortetracycline in the sample.

    6. Cutting-Edge Solutions for Chlortetracycline Measurement

    Serial Number: 6

    In the modern biopharmaceutical industry, the demand for precise and reliable chlortetracycline measurement has led to the development of cutting-edge solutions. Companies specializing in this field offer anti-chlortetracycline antibodies and competitive antigens that are scientifically validated, ensuring accurate and trustworthy results. These innovative solutions aid various stakeholders, from regulatory bodies to food producers, in upholding the highest standards of food safety and animal health.

    7. Conclusion

    Serial Number: 7

    In conclusion, chlortetracycline's pivotal role in veterinary drug residues and additives is indisputable. Its ability to combat bacterial infections in animals contributes significantly to the welfare of livestock and poultry populations. To maintain regulatory compliance, control antibiotic resistance, preserve animal health, and protect consumers, accurate monitoring of chlortetracycline levels is imperative. The utilization of advanced measurement techniques, coupled with the strategic use of anti-chlortetracycline antibodies and competitive antigens, ensures the integrity of the food supply chain and the sustainability of antibiotic use in veterinary medicine. As technology advances, the tools available for chlortetracycline measurement continue to evolve, providing even more precise and reliable results for the benefit of animal health and human safety.



    About GDU


    GDU

    GDU helps global diagnostic partners in high quality of raw material discovery, development, and application. GDU believes in Protein&antibody Innovation for more reliable diagnostic solutions.